AIB2 Components - Pattern Sequencer
|
|
Category: |
Decision Logic
|
|
Description: |
The pattern sequencer component provides functionality to send time-series patterns to its outputs. Each set of patterns is identified and triggered by a unique assignable integer value. When this value is presented to the component at run-time, the patterns commence.
In the component properties window, each output is represented by a row in the time-series table. Each column in the table corresponds to a 100ms time slice. By clicking on each cell, the respective output represented by that row will have its value set to ON (1) for that time-slice. Right clicking on the cell again will reverse the setting. Patterns can be set to automatically repeat by double clicking on the pattern name and setting the check box for repeat to on. New patterns can be added by clicking the Add pattern button. New Outputs can be added by clicking the Add output button. Test pattern sequences by dragging the time needle arrow at the top of the table. |
|
|
|
Inputs: 4 |
Enable
Boolean input of zero or non-zero value that either enables or disables the component. Default is ON.
Pattern Number
A unique integer value that represents the time sequence pattern to execute.
Stop
A boolean input used to stop the current execution of the sequence. If non-zero, the pattern currently being executed will stop at the current needle position.
Reset
A boolean input used to rest the current execution of the sequence to the first frame. If non-zero, the pattern currently being executed will stop and move the needle position to 0.
|
|
|
|
|
Outputs: 0 |
|
|
|
|
Components in Same Category: |
Neural Network Segmenter Single Out Segmenter Multple Outs Feedback Flow Pattern Generator Pattern Analyzer Pattern Recorder Decision Matrix Target Input Comparator State Machine Simple States Awareness Hub State Machine Timer
|
|
Sample Files with this Component: |
|
|
|
|